Microscope Accessories and Replacement Parts
General accessories and parts for use with microscopes. Products include lens oil, lens cleaner, slide dispensers, microscope covers, vessel holders, light cubes, and flow cells.
Many parts of your microscope can be updated or replaced including microscope lamps, lenses, and eyepieces. Replacement lamps, light sources, and power cords can extend the working lives of your microscopy equipment. New or replacement objectives and lenses can help increase the total magnification available with your microscope.
Add greater magnification or exchange your eyepiece for one with a reticule to more easily estimate the sizes of the items being viewed.
Replace or update your mechanical stage or clamps or add cell culture vessel adapters to facilitate specimen positioning.
Condensers can also be replaced, and conversion kits are available to add phase contrast, polarization, fluorescence, or other capabilities to your current system.
Some microscopes can be adapted for use with still or video cameras. Look for cameras and adapters designed for your specific microscope brand. Film and documentation-related products may also be available to support your record-keeping.
Temporary, semi-permanent, and more long-term slide storage options include:
- Slide racks that securely hold slides during staining procedures
- Folding fiberboard or plastic slide holders with horizontal indentations that keep microscope slides in place
- Slide storage boxes with vertical dividers; made from fiberboard, plastic, and wood and available in multiple sizes
- Slide holders and mailers for transporting slides safely
- Slide storage systems and cabinets for large quantities of slides or archival storage
- (1)
- (4)
- (4)
- (4)
- (1)
- (1)
- (1)
- (6)
- (3)
- (1)
- (5)
- (4)
- (9)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (14)
- (5)
- (6)
- (2)
- (1)
- (1)
- (2)
- (1)
- (9)
- (2)
- (1)
- (1)
- (2)
- (4)
- (1)
- (1)
- (16)
- (3)
- (4)
- (1)
- (3)
- (2)
- (1)
- (1)
- (5)
- (2)
- (1)
- (1)
- (1)
- (11)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (3)
- (1)
- (1)
- (5)
- (1)
- (2)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (3)
- (1)
- (2)
- (1)
- (1)
- (1)
- (1)
- (3)
- (1)
- (1)
- (7)
- (1)
- (1)
- (1)
- (1)
- (2)
- (1)
- (2)
- (5)
- (6)
- (1)
Filtered Search Results
Electron Microscopy Sciences Low Magnification SEM Test Specimen Tin On Carbon, JEOL Stub
This low magnification test has a size range of 1 - 10μm for table-top SEM. Has a magnification range of 250-5,000x. Can be used on FESEM and FIB as well.
Type: JEOL Stub
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Veco Hexagonal 200 mesh Copper Grid
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter, 0.8 mil thickness.
Grid: Copper
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Strip Aperture JEOL, 100-200-300 µm holes, 9.0 x 2.35 x 0.10 mm
Strip apertures made from Platinum-Iridium (95:5).
Holes: 100-200-300 µm
Dimensions: 9.0 x 2.35 x 0.10 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Ted Pella Inc PELCO Center-Marked Grids, 200 mesh, 3.0mm O.D., Copper, 100/vial
The PELCO Grids are usually somewhat thicker than similar TEM grids made by electro plating processes which makes them stiffer and easier to handle without the danger of bending, but still maintain a good definition of the grid bars. The wide rims (350-400µm) on the PELCO Grids provide additional stiffness and minimize the potential of interfering with the sample when picking up and handling the grids with tweezers
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Veco Square Mesh Oyster Grid D75, Nickel
Veco Grids offer superior handling characteristics. Plus, with a 0.8 mil thickness, Veco Grids are the most rigid grids available. 3.05 mm diameter.
Material: Nickel
Pitch: 333 µm
Holes: 283 µm
Bar: 50 µm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences AMD-FH Microscope Workstation, 120 x 75 cm, Ferromagnetic SS Surface
These isolation tables support most of the larger microscopes and their support equipment. The air isolation platform effectively removes most removes most vibrations. The rigid frame has levelling feet which ensure the table is in excellent contact with the floor. The damped rolling diaphragm isolators have a low natural frequency of 2Hz which effectively isolates out vibrations above 6Hz, well below the frequencies at which typical building vibrations begin to occur. Full Active table with self-levelling and platform guards.
Size: 120 x 75 cm
Surface: Ferromagnetic SS
Type: Active Air Self Leveling
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Cylinder Mount SEM 3/8" head, 3/16" height, Aluminum
Cylinder specimen mounts are for use with JEOL scanning electron microscopes. The mounts are made from ultra-pure aluminum with a standard lathe finish.
Head: 3/8"
Pin height: 3/16"
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Walton & Beckett Graticule G22, 19 mm, 3:1 ratio
The Walton and Beckett graticule is for counting fibrous dust (asbestos or glass fibers) and particularly where the majority of fibers to be counted are shorter than 5 microns. The circle is divided into four by two diametrical lines scaled in units of 5 and 3 microns respectively. 3 and 5 microns are the critical measurements of fiber lengths and diameters used in fiber counting. Walton and Beckett include shapes with an aspect ratio of 3:1 or 5:1 for comparing to fibers.
IMPORTANT NOTE: The circle on these Walton & Beckett graticules must represent 100 microns at the stage and each one must be manufactured to the individual instrument. 3:1 ratio is useful where the majority of fibers to be counted are shorter than 5 um.
Size: 19 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences British Standard Graticle NG10, 19mm
In this graticule the circle areas double progressively, hence the diameters alter by Root 2, so that the size classes can form a continuation of the standard series of sieves for particle sizing. Each particle is assigned to a size class defined by two adjacent circles, which represent the size limits of that class. Thus the distribution of size is obtained in terms of the diameter of circles having the same projected area as the particles. This method will cover particles in the range 150 micron to 0.38 micron. The size distributions with respect to their number and weight are determined separately. Final results are calculated as cumulative percents.
Originally designed by the National Coal Board for use in coal mining.
Size: 19 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences EMS Platinum Aperture with 70 µm hole, 0.53 mm thick
Platinum apertures are easily cleaned by either an aperture flamer or over a bunsen burner in the open air. We maintain a wide variety of Platinum Drilled Apertures in stock with different configurations suiting all of your needs. Nominal hole diameter: +/- 1 micron. Disc diameter: +/- 10 microns. Disc thickness: +/- 10 microns
Size: 70 µm
O.D.: 2 mm
Thickness: 0.53 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Speirs-Levy Eosinophil Counting Chamber
Speirs-Levy eosinophil is used for counting eosinphil in blood and may also be used for performing cell counts in spinal fluids or other media.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences TEM Screen Recoating Zeiss EM10 Small
For optimum viewing, fluorescent screens should be recoated regularly. Viewing screens are easily damaged by the electron beam, especially at high accelerating voltages where knock-on damage can be severe. A proprietary process where 1 to 2 micron particles of phosphor are deposited on the screen and produce the highest possible resolution.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Structure Probe Inc HOPG SPI Supplies Brand Grade SPI-2 10x10x1 mm Thick, Package of 1 Piece
Grade SPI-2. Very similar to ZYB(see below), this grade exhibits a mosaic angle as small as 0.8° +/- 0.2°. This grade is slightly less highly ordered than SPI-1 but is acceptable for most users. The lateral grain size can be up to 0.5 mm but can be as large as 1 mm. Note that this grade is slightly less "cleavable" than the 0.4° mosaic spread product, that is, SPI-1. Most workers find this grade more than suitable for all but the most critical samples, but priced low enough for routine use. Some users prefer this grade to SPI-1 because the cleavage steps are slightly wavy, so samples are held in place better (e.g. better adhesion). Dimensions = 10 mm x 10 mm x 1 mm
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences SEM Aluminum Tungsten Dendrites
The various spacings created by the dendritic structure give the gap test, and the topographical arrangement of the dendrites leads to the gray level test. The specimen is non-magnetic, vacuum clean. It is most useful for working in the probe size range of 25 to 75 nm. Supplied unmounted.
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More
Electron Microscopy Sciences Crossed Scale Microscope Graticle NE70 (imperial), 26 mm, 0.8' with 400 divisions of 0.002"
Used as a horizontal and a vertical scale, they are especially useful when interested in measurement in different axis. Crossed Micrometer scale (imperial).
Size: 26 mm
Divisions: 0.8' with 400 divisions of 0.002"
Surface: Chrome image
Non-distribution item offered as a customer accommodation; additional freight charges may apply.
Learn More